當(dāng)前位置:首頁技術(shù)文章博士力士樂伺服器維修EC-HCS03驅(qū)動(dòng)代碼講解及對策

博士力士樂伺服器維修EC-HCS03驅(qū)動(dòng)代碼講解及對策

更新時(shí)間:2023-02-15點(diǎn)擊次數(shù):1399

E250 Heatsink Overtemperature Warning散熱器過熱警告。

Description:說明:

The temperature of the heatsink in the drive controller has reached the

maximum allowable temperature. Within a time frame of 30 seconds, the

drive follows the command value input. Consequently, there exists the

possibility to shut down the motor with the control so that it remains true to

the process. (For example close the operation, leave the collision area,

etc.) After 30 seconds, the parameter "Best Possible Deceleration, P-0-

0119" set reaction appears during operation.


驅(qū)動(dòng)器控制器中的散熱器溫度已達(dá)到最高允許溫度。在30秒內(nèi)驅(qū)動(dòng)器遵循命令值輸入。因此,存在使用控制裝置關(guān)閉電機(jī)的可能性,使其保持正確這一過程。(例如,關(guān)閉操作,離開碰撞區(qū)域,30秒后,參數(shù)“最佳可能減速,P-0-0119“設(shè)置反應(yīng)在操作過程中出現(xiàn)。


Cause:原因:

1. Deficiency of the drive's internal blower.

2. Deficiency of the control cabinet’s climate control.

3. Incorrect control cabinet dimensioning regarding the

head ventilation

1.驅(qū)動(dòng)器內(nèi)部鼓風(fēng)機(jī)不足。

2.控制柜氣候控制不足。

3.控制柜尺寸不正確頭部通風(fēng)

8.29力士樂伺服驅(qū)動(dòng)器1.jpg


Remedy:

For 1. If the blower fails exchange the drive controller.

For 2. Install climitization feature to the cabinet.

For 3. Check the dimensions of the control cabinet.

對于1。如果鼓風(fēng)機(jī)出現(xiàn)故障,更換驅(qū)動(dòng)控制器。

對于2。為機(jī)柜安裝氣候調(diào)節(jié)功能。

對于3。檢查控制柜的尺寸。


F895 4 kHz Signal Error4 kHz信號錯(cuò)誤。

Description:

The 4kHz signal is synchronized with the software processing for creation

of the resolver signal. This error message is created when

synchronization occurs improperly.

4kHz信號與用于創(chuàng)建的軟件處理同步旋轉(zhuǎn)變壓器信號的。此錯(cuò)誤消息是在以下情況下創(chuàng)建的同步發(fā)生不正確。


Cause:

1. The synchronization of the resolver controller voltage is invalid

in regards to the software.

2. The error can be produced through an electrical discharge.

1.分解器控制器電壓同步無效關(guān)于軟件。

2.該誤差可通過放電產(chǎn)生。


Remedy:補(bǔ)救措施:

For 1. Exchange drive controller and return for testing.

For 2. Power down and then on. If this in not successful; exchange 

drive controller.

對于1。更換驅(qū)動(dòng)器控制器并返回測試。

對于2。關(guān)閉電源,然后打開。如果這不成功;交換驅(qū)動(dòng)控制器。